battery tester 5V 6A Cell capacity tester
Equipment Function Introduction:
1.Single point independence allows for independent control of each battery testing channel. 2.Charging and discharging tests, capacitance and cycle life performance tests, etc.
3.Battery reverse connection hardware protection and software protection functions.
4.The equipment accuracy is 0.05%, ensuring high stability in measurement and operation.
5.TCP/IP network communication mode, with the fastest data recording time of 0.1 seconds per time. 6.The software has powerful functions and a user-friendly human -machine interface.
7.The voltage and current loop is designed independently and adopts a four wire testing interface. 8.Ensure a smooth and safe transition between charging and discharging.
9.Equipped with power -off hardware and software protection, as well as data protection functions, incoming calls can continue to connect data, and test data is not lost. 10.Equipped with activation and speed regulation functions.
11.Modular design concept, easy to maintain.
12.Software overvoltage, undervoltage, overcurrent, undervoltage, overcurrent protection, etc.
13.The test terminates abnormally, and the software can continue testing after the exception is resolved.
14.The upper computer software has systematic data statistics and sorting and grouping functions, improving the efficiency of the production line. 15.Multi channel devices can be split and used in parallel, and can be customized.
16.Constant current charging/discharging test (with protective board battery).
17.Temperature detection, can be equipped with a temperature measurement system, and can be customized. 18.Can be equipped with multiple auxiliary voltages and auxiliary temperatures. Customizable.
19.The fixture is flexible and adjustable, with strong compatibility.
Technical specifications | |
communication method | RJ45 (network) |
Channel control mode | Single point independent control |
Test voltage range | 0. 1V ~5V |
Test current range | 0. 1A ~6A |
Simultaneous detection quantity | 8 |
Channels per unit | 8 |
The Number of floors in a Cabinet (Standard) | 10 |
Charging energy saving efficiency | 80% |
Comprehensive energy saving efficiency | 75% |
Voltage accuracy | ±(0.05%RD+0.05%FS) |
Current accuracy | ±(0.05%RD+0.05%FS) |
main temperature | According to the specific equipment, each channel can be customized and equipped with 1 channel. |
Voltage resolution | 1mV |
Current resolution | 1mA |
Temperature resolution | 0.1 ℃ |
Input power | AC220N ±10%/50Hz (cabinet power supply mode: three -phase five-wire) |
sampling time | Single box sampling frequency 10mS |
Record time | 100mS~65535 S |
Charging mode | Constant current and voltage limiting, constant current and constant voltage, constant power charging, constant current overcharge test,Constant resistance charging, constant resistance charging (for batteries with protective plates) |
Charge cutoff conditions | voltage, current, time, capacity, temperature |
discharge mode | Constant current discharge, constant power discharge, constant current over-discharge testConstant resistance discharge, |
constant resistance discharge (for batteries with protective plates) | |
Discharge cutoff bar | voltage, current, time, capacity, temperature |
Number of steps in a single cycle | 100 steps, with nested loop function (10 levels) |
Circuit configuration | Modular structure design for easy replacement and maintenance |
Software and hardware guarantee | Reverse connection protection, overvoltage protection, overcurrent protection, overtemperature protection, undervoltage protection, short circuit protection |
Standard Package | CAN communication cable, Cell Tester power cable , alligator clips or polymer clips (option) |